Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Ophthalmol ; 15: 2317-2325, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34113075

RESUMO

PURPOSE: To describe surgical technique and report short-term visual outcomes after suture-fixation of a single-piece eyelet-toric (SET) intraocular lens (IOL) for treatment of concurrent aphakia and astigmatism. DESIGN: Retrospective, noncomparative, and non-consecutive case series. METHODS: This was a case series of eleven eyes who underwent successful SET. Eligible eyes had loss of capsular support or aphakia with a minimum of symmetric corneal astigmatism 1.75 diopters (D). Outcome measures included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), magnitude of residual refractive cylinder, and complications resulting from the SET procedure. RESULTS: Preoperative UDVA and CDVA in logMAR scale were 1.46 and 0.45, respectively. Mean preoperative keratometric and refractive cylinder were 3.67 D and 2.52D, respectively. Postoperative UDVA and CDVA were 0.51 and 0.27, respectively, three months after surgery (POM3). Residual refractive cylinder at POM3 was 0.93 D. CONCLUSION: SET technique reduced refractive cylinder and improved UDVA and CDVA. SET may be adapted by surgeons using a readily available IOL and familiar scleral-fixation maneuvers.

2.
Am J Ophthalmol ; 221: 273-278, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32777376

RESUMO

OBJECTIVE: To report clinical features and visual outcomes following eyelet fractures of scleral-sutured enVista MX60 (Bausch + Lomb) intraocular lenses (IOL). DESIGN: Retrospective, multi-center, multi-surgeon, observational case series. METHODS: Study Population: Patients with scleral-sutured enVista MX60 IOLs that experienced either an intraoperative or post-operative eyelet fracture associated with dislocation or subluxation. PROCEDURES: All records were reviewed for patients with a dislocated or subluxed scleral-sutured enVista MX60 IOL. Clinical features and outcomes were gathered. Main Outcome Measures: Clinical setting, surgical technique, complications, and visual acuity. RESULTS: A total of 25 scleral-sutured enVista MX60 IOLs displacements secondary to eyelet fractures in 23 eyes of 23 patients were included. There were 20 IOLs that sustained a postoperative fracture and 5 IOLs that sustained an intraoperative fracture. Of the postoperative fractures, 7 were dislocated and 13 were subluxed. Gore-Tex was the suture of choice for 19 of the postoperative fractures and all 5 of the intraoperative fractures, and Prolene was used for 1 postoperative fracture. The mean time until postoperative fracture was 96 ± 125 days, and the median time was 61 (IQR 48-144) days. Of the postoperative fractures, new MX60s were sutured in 10 patients, and 2 of them experienced repeat displacements due to a new eyelet fracture. In the intraoperative fracture group, new MX60s were sutured in 4 patients and an Akreos AO60 lens was placed in the 5th patient. The mean preoperative best-corrected logMAR visual acuity for all patients improved from 1.2 ± 0.8 (20/317 Snellen equivalent) to 0.5 ± 0.5 (20/63 Snellen equivalent) at most recent follow-up after lens replacement. CONCLUSIONS: Scleral-sutured MX60 intraocular lenses can experience intraoperative or postoperative eyelet fractures, resulting in lens subluxation or dislocation. Surgeons should be aware of this complication when evaluating secondary intraocular lens options.


Assuntos
Migração do Implante de Lente Intraocular/etiologia , Complicações Intraoperatórias , Implante de Lente Intraocular/métodos , Complicações Pós-Operatórias , Falha de Prótese/etiologia , Esclera/cirurgia , Técnicas de Sutura , Adulto , Idoso , Idoso de 80 Anos ou mais , Migração do Implante de Lente Intraocular/diagnóstico , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Facoemulsificação , Estudos Retrospectivos , Fatores de Tempo , Acuidade Visual/fisiologia , Vitrectomia
3.
Cornea ; 40(7): 903-906, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32947410

RESUMO

PURPOSE: In our report, we present a suspected case of donor-derived Acanthamoeba keratitis after deep anterior lamellar keratoplasty. To the authors' knowledge, there have been no confirmed cases of Acanthamoeba keratitis transmission through corneal transplantation. METHODS: Deep anterior lamellar keratoplasty was performed on the right eye of a 33-year-old man with severe bilateral keratoconus and an intolerance to all forms of contact lenses. The postoperative visual acuity deteriorated, while inflammation, rising ocular pressure, increasing corneal thickness, and severe eye pain began to present. Confocal imaging revealed hyperreflective cysts and trophozoite figures representative of amoebic keratitis. Despite an additional penetrating keratoplasty, antiamoeba therapy, and corneal crosslinking, the patient's condition worsened, resulting in stromal melt and corneal perforation. Emergent combined surgery of temporary keratoprosthesis, vitrectomy, lensectomy, and iridectomy was performed, along with Ahmed valve shunt placement and another penetrating keratoplasty. RESULTS: The infection was resistant to aggressive antiamoeba therapy, but after the emergent combined surgery, the graft re-epithelialized quickly and has since remained clear, with no presence of keratitis. CONCLUSIONS: Several signs led us to believe that this case was donor-derived. There was little opportunity for graft exposure to the amoeba, and deep amoebic cysts and trophozoites were present on postoperative week 1-a highly unusual time course and depth of invasion for primary amoebic infection. In addition, pathological analysis revealed cysts only within the confines of the donor tissue and none in the recipient; Acanthamoeba cysts would have been present in the recipient rim tissue if the infection originated from the patient himself.


Assuntos
Ceratite por Acanthamoeba/transmissão , Transplante de Córnea/efeitos adversos , Transmissão de Doença Infecciosa , Doadores de Tecidos , Acanthamoeba/isolamento & purificação , Ceratite por Acanthamoeba/diagnóstico , Ceratite por Acanthamoeba/cirurgia , Adulto , Substância Própria/parasitologia , Feminino , Humanos , Masculino , Microscopia Confocal , Pessoa de Meia-Idade , Acuidade Visual
4.
Bioorg Med Chem ; 24(15): 3267-75, 2016 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-27301675

RESUMO

One of the hurdles in the discovery of antibiotics is the difficulty of linking antibacterial compounds to their cellular targets. Our laboratory has employed a genome-wide approach of over-expressing essential genes in order to identify cellular targets of antibacterial inhibitors. Our objective in this project was to develop and validate a more sensitive disk diffusion based platform of target identification (Target Identification Platform for Antibacterials version 2; TIPA II) using a collection of cell clones in an Escherichia coli mutant (AS19) host with increased outer membrane permeability. Five known antibiotics/inhibitors and 28 boron heterocycles were tested by TIPA II assay, in conjunction with the original assay TIPA. The TIPA II was more sensitive than TIPA because eight boron heterocycles previously found to be inactive to AG1 cells in TIPA assays exhibited activity to AS19 cells. For 15 boron heterocycles, resistant colonies were observed within the zones of inhibition only on the inducing plates in TIPA II assays. DNA sequencing confirmed that resistant clones harbor plasmids with fabI gene as insert, indicating that these boron heterocycles all target enoyl ACP reductase. Additionally, cell-based assays and dose response curved obtained indicated that for two boron heterocycle inhibitors, the fabI cell clone in AG1 (wild-type) host cells exhibited at least 11 fold more resistance under induced conditions than under non-induced conditions. Moreover, TIPA II also identified cellular targets of known antibacterial inhibitors triclosan, phosphomycin, trimethoprim, diazaborine and thiolactomycin, further validating the utility of the new system.


Assuntos
Compostos de Boro/química , Compostos Heterocíclicos/química , Compostos de Boro/farmacologia , Sistemas de Liberação de Medicamentos/métodos , Escherichia coli/efeitos dos fármacos , Compostos Heterocíclicos/farmacologia
5.
Cornea ; 33(8): 785-9, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24915017

RESUMO

PURPOSE: The aim of this study was to assess and compare the association of glaucoma therapy with graft survival after performing penetrating keratoplasty (PKP) and Descemet stripping automated endothelial keratoplasty (DSAEK). METHODS: A retrospective chart review was performed of cases: primary PKP from January 1, 2003, to December 31, 2005, or primary DSAEK from January 1, 2006, to December 31, 2008. Eyes with a surgical indication of pseudophakic corneal edema were included in the statistical analysis. Eyes were stratified by glaucoma treatment into those with (1) no glaucoma treatment, (2) medical therapy only, or (3) surgical intervention. The main outcome measure was graft survival. RESULTS: Fifty-seven PKP-operated and 156 DSAEK-operated eyes met the inclusion criteria. After PKP and DSAEK, respectively, the 5-year Kaplan-Meier graft survival was 94.7% and 93.8% in eyes with no glaucoma treatment (P > 0.99), 93.8% and 96.3% in eyes with medical therapy only (P > 0.99), and 56.8% and 50% in eyes with surgical intervention (P > 0.99). After both procedures were performed, graft survival was significantly worse in eyes with surgical intervention compared with that in eyes with no glaucoma treatment (P < 0.0001) or in eyes with medical therapy alone (P < 0.0001). CONCLUSIONS: PKP and DSAEK have comparable graft survival in eyes without glaucoma management and in those with comparable glaucoma management.


Assuntos
Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Glaucoma/terapia , Sobrevivência de Enxerto/fisiologia , Ceratoplastia Penetrante , Adulto , Idoso , Idoso de 80 Anos ou mais , Anti-Hipertensivos/uso terapêutico , Edema da Córnea/fisiopatologia , Edema da Córnea/cirurgia , Feminino , Cirurgia Filtrante , Glaucoma/tratamento farmacológico , Glaucoma/cirurgia , Implantes para Drenagem de Glaucoma , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Pseudofacia/fisiopatologia , Pseudofacia/cirurgia , Estudos Retrospectivos
6.
Appl Microbiol Biotechnol ; 98(12): 5551-66, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24622888

RESUMO

One of the challenges in antibiotic lead discovery is the difficulty and time-consuming task of determining the mechanism of action (MOA) of antibacterial compounds. In this report, we describe the development and validation of a facile and inexpensive assay system utilizing disk diffusion of inhibitors on solid agar medium embedded with mixed pools of a comprehensive collection of Escherichia coli clones each containing a plasmid-borne inducible essential gene from E. coli. From individual clones, pilot small-scale (48 or 50 clones) assays, to full-scale target identification platform for antibacterials (TIPA) system, involving a variety of assay formats (liquid vs solid media, individual vs mix clones), we demonstrate that elevated resistance phenotypes of relevant cell clones were highly specific. In particular, the TIPA system was able to reveal cellular targets of several known antibacterial inhibitors: cerulenin, diazaborine, indolmycin, phosphomycin, and triclosan. Complementary to several existing MOA profiling schemes, the TIPA system offers a simple and low-cost method for elucidating the target proteins of antibacterial inhibitors, thus will facilitate discovery and development of novel antibacterial compounds to combat multidrug-resistant bacterial pathogens.


Assuntos
Antibacterianos/farmacologia , Técnicas Bacteriológicas/métodos , Descoberta de Drogas/métodos , Escherichia coli/efeitos dos fármacos , Fenômenos Farmacológicos , Ágar , Meios de Cultura/química , Escherichia coli/genética , Escherichia coli/crescimento & desenvolvimento
7.
Cornea ; 32(3): 273-9, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22475643

RESUMO

PURPOSE: To evaluate the efficacy, refractive predictability and stability, and complications of photorefractive keratectomy (PRK) with adjunctive mitomycin C (MMC) in patients with postkeratoplasty anisometropia. METHODS: A retrospective review was carried out of all cases of PRK performed for postkeratoplasty anisometropia with the VISX Star S4 excimer laser with MMC between January 1, 2004, and December 31, 2008. The main outcome measures were best spectacle-corrected distance visual acuity (CDVA) and patient tolerance of full spectacle refractive correction. Secondary outcome measures were uncorrected distance visual acuity (UDVA), refractive accuracy and stability, and complications. RESULTS: Twenty cases met the inclusion criteria. At 6 months, the spectacle CDVA had improved from a preoperative mean of 20/50 to 20/30 (P = 0.01). Ten eyes (50%) gained 2 or more lines of CDVA. Eighteen eyes (90%) had a CDVA of 20/40 or better. All 20 patients (100%) were subjectively satisfied with full binocular spectacle correction. There was an improvement in UDVA from a preoperative mean of 20/282 to 20/52 (P < 0.001). Thirteen patients (65%) had an UDVA of 20/40 or better. There was a reduction in the mean refractive spherical equivalent from -5.2 to -0.9 diopters (D), in myopia from -7.6 to -1.8 D, and in astigmatism from 4.9 to 2.0 D. No significant change in visual acuity or refractive error occurred between 3 and 12 months. No sight-threatening complications occurred. One eye (5%) lost 2 lines of CDVA. CONCLUSIONS: PRK with adjunctive MMC is an effective method of reducing postkeratoplasty anisometropia and providing satisfactory spectacle rehabilitation.


Assuntos
Anisometropia/cirurgia , Ceratoplastia Penetrante/efeitos adversos , Lasers de Excimer/uso terapêutico , Ceratectomia Fotorrefrativa , Complicações Pós-Operatórias , Adulto , Idoso , Alquilantes/administração & dosagem , Anisometropia/tratamento farmacológico , Anisometropia/etiologia , Óculos , Feminino , Humanos , Complicações Intraoperatórias , Masculino , Pessoa de Meia-Idade , Mitomicina/administração & dosagem , Estudos Retrospectivos , Resultado do Tratamento , Transtornos da Visão/reabilitação , Acuidade Visual/fisiologia
8.
J Ocul Biol Dis Infor ; 1(1): 12-8, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19081745

RESUMO

The carotenoids lutein and zeaxanthin are believed to protect the human macula by absorbing blue light and quenching free radicals. Intestinal malabsorption syndromes such as celiac and Crohn's disease are known to cause deficiencies of lipid-soluble nutrients. We hypothesized that subjects with nutrient malabsorption syndromes will demonstrate lower carotenoid levels in the macula and blood, and that these lower levels may correlate with early-onset maculopathy. Resonance Raman spectrographic (RRS) measurements of macular carotenoid levels were collected from subjects with and without a history of malabsorption syndromes. Carotenoids were extracted from serum and analyzed by high performance liquid chromatography (HPLC). Subjects with malabsorption (n = 22) had 37% lower levels of macular carotenoids on average versus controls (n = 25, P < 0.001). Malabsorption was not associated with decreased serum carotenoid levels. Convincing signs of early maculopathy were not observed. We conclude that intestinal malabsorption results in lower macular carotenoid levels.

9.
J Cataract Refract Surg ; 34(8): 1400-2, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18655995

RESUMO

PURPOSE: To assess how flow and bottle height affect postocclusion surge in the Infiniti (Alcon, Inc.) and Millennium (Bausch & Lomb) peristaltic machines. SETTING: John A. Moran Eye Center Clinical Laboratories, University of Utah, Salt Lake City, Utah. METHODS: Postocclusion anterior chamber depth changes were measured in human eye-bank eyes using A-scan. Surge was simulated by clamping the aspiration tubing and releasing it at maximum vacuum. In both machines, surge was measured (1) with aspiration held constant at 12 mL/min and bottle heights at 60, 120, and 180 cm and (2) with bottle height held constant at 60 cm and aspiration rates at 12, 24, and 36 mL/min. RESULTS: Surge decreased approximately 40% with each 60 cm increase in bottle height in the Infiniti. It was constant at all bottle heights in the Millennium. At 12 and 24 mL/min aspiration rates, surge in the Millennium was less than half that in the Infiniti (P<.001). CONCLUSIONS: Postocclusion surge decreased linearly with increasing bottle height in the Infiniti system and was relatively constant with increasing bottle height in the Millennium system. The Millennium may offer a more stable phacoemulsification platform with respect to surge at a higher aspiration rate.


Assuntos
Drenagem , Pressão Hidrostática , Facoemulsificação/instrumentação , Pressão , Curetagem a Vácuo , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...